鼠爪肿胀测定仪(肢体肿胀测试仪,鼠爪炎症测试,plethysmometer paw volume meter for mice and rats)(测试评估大鼠或小鼠后肢的痛觉和发炎,测量精准,更多详情敬请来电咨询)
型号:520mr
鼠爪体积测量仪用来衡量消炎药的有效性。使用时,讲大鼠、小鼠的爪子浸入含有特殊细胞的水中,由于浸泡水的压力发生了变化。压力的变化会被校准,并显示在特殊的电子监视器上。这种检测形式可以消除由于重复浸入发生导电性的改变而产生的改变,这种情况在类似的其他仪器上发现过。测试结果直接显示在lcd上(大鼠精确到0.01毫升、小鼠精确到0.001毫升)。无论是用电池还是用9v或12v的适配器,该设备表现稳定,操作安全。
paw volume meter enables researchers to measure the effectiveness of anti-inflammatory agents and agents to reduce edemic conditions. in use, the paw is inserted into plain water, which contains a special water cell of which the pressure is changed due to the immersion. this pressure change is calibrated in ml and shown on a special electronic monitor. this form of detection eliminates changes due to conductivity alterations at repeated insertions as found on comparable units. the measurements are shown on the units lcd readout in .01ml for rats and .001ml for mice. the unit is stable and can be safely operated either on its own battery or on a line adapter at 9 or 12 v. the unit is stable and can be safely operated either on its own battery or on a line adapter at 9 or 12 v.
鼠爪肿胀测定仪主要特点:
ø no wetting solution needed
ø one calibration/yr.
ø battery operated
鼠爪肿胀测定仪型号参数:
part # |
description |
520mr |
plethysmometer (paw volume) meter mice rat |
520a |
plethysmometer - water cell, plexi-glas, cable only |
|
部分参考文献:
iitc鼠爪肿胀仪被全世界各研究单位广泛应用,在各类专业期刊,如《pain》《neuroscience》《behavioural brain research》《molecular cancer therapeutics》等国际权威杂志上发表了数千篇论文。
s leo, r d'hooge, t meert - behavioural brain research, 2010 - elsevier
... a withdrawal response was calculated for each animal from three measurements on both hind
paws. ... inflammatory response produced by cfa, paw edema was measured using a
plethysmometer (iitc inc ... acetone was sprayed onto the plantar surface of the left hind paw with ...
d dubois, l gendron - european journal of neuroscience, 2010 - wiley online library
... behavioral testing. plethysmometer. to evaluate the level of inflammation induced by cfa
injection in ppta −/− and ppta +/+ mice, the volume of the hind limbs was measured using
a plethysmometer (iitc life science inc., woodland hills, ca, usa). ...
ay fan, l lao, rx zhang, an zhou, lb wang… - journal of …, 2005 - elsevier
... et al., 1997). paw volume was measured every other day between days 16 and 24
with a plethysmometer (iitc inc., woodland hills, ca), which consists of two vertical,
interconnected, water-filled perspex cells. the paw to be ...
n saghafi, dk lam, bl schmidt - neuroscience letters, 2011 - elsevier
... tumor growth was measured using a 520 m plethysmometer (iitc life sciences, woodland
hills) to determine the paw volume. the animal's tumor-bearing paw was inserted into a water
cell, which measures the change in pressure due to immersion. ...
y ye, d dang, j zhang, ct viet, dk lam… - molecular cancer …, 2011 - aacr
... tumor size and body measurement. mouse hind-paw volume was measured by using
a plethysmometer (iitc life science). tongue tumor volume was calculated at the end
of the experiment by multiplying tumor length by width by thickness. ...
sk mishra, s holzman, ma hoon - the journal of neuroscience, 2012 - soc neuroscience
... thirty minutes after injection of peptides, paw edema was measured using a
plethysmometer (iitc) and thermal and mechanical sensitization measured by
hargreaves and von frey apparatus assays (ugo basile), respectively. ...
gj amabeoku, j kabatende - advances in pharmacological sciences, 2011 - hindawi.com
... 40 min. the volume of the right hind paw was measured before and then after the
injection of carrageenan at 30 min intervals for 4 h by volume displacement method
using plethysmometer (iitc life sciences, usa). group ii ...
ct viet, y ye, d dang, dk lam, s achdjian, j zhang… - pain®, 2011 - elsevier
... the results of the 6 values were averaged for each paw for that day. paw volume measurements
were performed with a plethysmometer (iitc life sciences). the paw was inserted into a water
cell, of which the pressure is changed due to the immersion. ...
s khan, mh mehmood, ana ali, fs ahmed… - journal of …, 2011 - elsevier
... after 30 min of treatment, 50 μl of 1% carrageenan was administered into the sub-plantar side
of the right hind paw. the volume of the right hind paw was measured (winter et al., 1962) using
a plethysmometer (iitc inc. life sciences, woodland hills, ca). ...
c agyare, ga koffuor, ve boamah, f adu… - evidence-based …, 2012 - hindawi.com
... groups ( ). the initial foot volumes of the chicks were measured using plethysmometer
(iitc life science inc., ca, usa) after which 0.01 ml of 2% carrageenan was injected