甩尾测痛仪 -尊龙凯时网娱乐官网

上海玉研科学仪器有限公司

电话:021-35183767
   021-54377179

传真:021-35183767-8008

qq:2113136797

地址:上海市闵行区兴梅路485号 xingmei rd 485,shanghai,china

当前位置: > 疼痛与炎症研究 > 甩尾测痛仪
疼痛与炎症研究

甩尾测痛仪

时间:2016-09-17来源:本站作者:玉研仪器

详细介绍

甩尾测痛仪(疼痛甩尾测试,甩尾仪,tail flick test analgesia meter apparatus(测试动物疼痛反应时间和动物对镇痛药物的疼痛反应极限,使用简便,更多详情敬请来电咨询)

 

型号:33型


疼痛甩尾测试仪用于测试动物疼痛反应时间和动物对镇痛药物的疼痛反应极限实验过程中检测到动物尾部甩动后内置的计时器自动停止计时

 

the tail flick test apparatus meter measures latency and/or temperature threshold when detecting properties of narcotic and strong non-narcotic drugs on mice and rats. a built-in timer is automatically stopped when the animals’ tail flicks out of the beam of light, test result will be displayed on readout for viewing.

an overhead halogen light source is in a constant “on” (idle state). a pre-focused heat source supplies an area of 4x6mm stimulation to the tail. a built-in sensor in the tail groove detects the tail flick of the animal. the tail groove is a non-metallic material to avoid unnecessary conditioning of your animals; unlike other systems. if the animal does not flick their tail within the pre programmed cut-off time; the heat source shuts off automatically; avoiding tissue damage. built-in timer displays the reaction time in 0.01 second increments. control of system can be from either the front panel or supplied footswitch: start, stop and reset of tests.

 

疼痛甩尾测试仪主要特点: 

 

ø 实时尾部温度/触发可选

ø 触发温度设置功能

ø 精确数字控制,时间精确度为0.01

ø 自动切断保护功能

ø 光束强度可调节,步进量1

ø 自动检测活动反应

ø 强制取消定时器功能

ø 数字显示功能

ø 标准计算机打印口输出

ø rs-232输出





相关文献:

t schneider, a roman, a basta-kaim, m kubera… - …, 2008 - elsevier

… adverse developmental consequences produced by early brain injuries, especially in animal
models of human … valproic acid have not been studied in the presented animal model of autism …
withdrawal test carried out using an analgesia meter apparatus (mod 33, iitc, inc, usa …

  

r karlsten, c post, i hide, jw daly - neuroscience letters, 1991 - elsevier

… the animals were used only once. testing of tail flick was performed using an iitc inc. model
33 analgesiameter, with the light focused on the tip of the tail [3]. the intensity of the beam was
adjusted to give a reaction time of 3-4 s before the it injection of the drug solutions …

t schneider, r przewłocki - neuropsychopharmacology, 2005 - nature.com

… the thermal paw withdrawal test was carried out using an analgesia meter apparatus (mod 33,
iitc, inc., usa) … aberrations described in this paper appear before puberty, which could distinguish the vpa rat model of autism from other animal models of psychiatric …

  

[pdf] 

j jurcovicova, m stancikova, k svik… - clinical and …, 2001 - clinexprheumatol.org

… they had free access to food. in group four aa was induced and the animals received 60%
of the food consumed by the arthritic rats (group 3) on the previous day … the pain threshold
was measured using the tail flick analgesia meter (model 33 iitc inc …

 

y yajima, m narita, m narita, n matsumoto, t suzuki - brain research, 2002 - elsevier

… each of the hind paws of mice was tested individually using a thermal stimulus apparatus (model
33 analgesia meter; iitc inc./life science … an aliquot of tissue sample was diluted with an equal volume of electrophoresis sample buffer (protein gel loading dye-2x …

  

[html] 

m nishiyori,  - molecular pain, 2008 - molecularpain.biomedcentral.com

… 10 μg in the neuropathic pain model, which is consistent with the previous study that … the ics model is a promising candidate for experimental fms or generalized pain syndrome models … thermal paw withdrawal test was carried out using a thermal stimulus (model 33 tail flick …

m kalinichev, kw easterling, sg holtzman - psychopharmacology, 2001 - springer

… an organism's responsiveness to stress has been exten- sively investigated in several rodent
models … previous findings by kehoe and blass (1986) provide indirect evidence indicating that
maternal … a light source was focused on the lower third of the tail (model 33, tail flick …


k starowicz, sa mousa, , a chocyk… - pharmacological …, 2009 - elsevier

… pwl) in response to noxious thermal stimuli using an analgesia meter (mod 33, iitc inc., landing, nj … the initial phase of the cci model of neuropathic pain involves inflammation around the nerve …restricted to the dorsal horns of the spinal cord, similar to previous studies [26 …

ar gintzler, br komisaruk - brain research, 1991 - elsevier

… a lamp mounted 8 cm above the tail and was maintained until a response was elicited or 10 s
had elapsed (iitc inc., model 33, landing, nj) … since in a previous study, there was no correlation between the magnitude of increase in tfl produced by vaginal stimulation and the …

  

yz gao, sy guo, qz yin, t hisamitsu… - the american journal of …, 2007 - world scientific

… previous studies have demonstrated that electroacupuncture (ea) at st36 acupoint could produce profound analgesia … recording the tail flick latency (tfl) induced by radiant heat using model 33 tail flick … briefly, 750 ng of fast recovery sample crna were mixed with 750 ng of …

  

[pdf] 

i pekarkova, s parara, v holecek, p stopka, l trefil… - physiol res, 2001 - biomed.cas.cz

… it was found in our previous research in the field of pain that after repeated painful … the tail-flick test (tf) (tail flick analgesia meter model 33, iitc inc., life science instruments, usa) measures the … sample preparation on the last day of the experiment (the 5th day), after all the …

  

k niikura, m narita, m narita, a nakamura, d okutsu… - neuroscience …, 2008 - elsevier

… paws of rats were tested individually using a thermal stimulus apparatus (model 33 analgesia
meter … in the present study, sample preparation was performed 10 days after partial sciatic … 2b).
consistent with many previous studies which have characterized afferent projections to …


[pdf] 

… - 2012 - inforesights.com

… antinocieptive activity of toddalia asiatica (l) lam. in models of central and peripheral pain … tail flick test a radiant heat tail-flick iitc inc. model 33 analgesiometer was used to measure response latencies according to the method described previously (corrêa et al., 1996) …




    您想了解更多详细资料吗?

    请与我们联系:

    tel021-35183767021-54377179

         18502129044

    qq3250431383

    微信:yuyanbio

    mail

    欢迎您的咨询!

 

网站地图